Uni-Trend UT201 Dokumentacja

Przeglądaj online lub pobierz Dokumentacja dla Multimetry Uni-Trend UT201. Uni-Trend UT201 multimeter Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 32
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
1
Model UT201/202: OPERATING MANUAL
Table of Contents
Title Page
Overview
Unpacking Inspection
Safety Information
Rules For Safe Operation
International Electrical Symbols
The Meter Structure
Rotary Switch
Functional Buttons
The Effectiveness of Functional Buttons
Display Symbols
Measurement Operation
A. DC Voltage Measurement
B. AC Voltage Measurement
C. Measuring Resistance
D. Testing Diodes
E. Testing for Continuity
F. Temperature Measurement
G. AC Current Measurement
Sleep Mode
Specifications
A. General Specifications
B. Environmental Restriction
Accuracy Specifications
A. AC Voltage
B. DC Voltage
C. Resistance
D. Continuity Test
E. Diode Test
F. Temperature
G. AC Current
Maintenance
A. General Service
B. Replacing the Battery
3
4
5
6
8
9
10
11
12
13
15
15
16
17
19
20
22
23
25
26
26
26
27
27
27
28
28
28
29
29
30
30
30
Przeglądanie stron 0
1 2 3 4 5 6 ... 31 32

Podsumowanie treści

Strona 1

1Model UT201/202: OPERATING MANUALTable of ContentsTitle PageOverviewUnpacking

Strona 2

Rotary SwitchBelow table indicated for information about the rotary switchpositions.RotarySwitchPositionFunctionAC/DC voltage measurement.: Diode test

Strona 3

Functional Buttons(1)Below table indicated for information about the functionalbutton operations.AC voltage measurement.l Press HOLD

Strona 4 - Unpacking Inspection

The Effectiveness of Functional ButtonsNot every functional buttons can be used on every rotaryswitch positions. Below two tables describe which func

Strona 5

Display Symbols(1) (see figure 2)No. Symbol Meaning3The battery is low. Warning: To avoid false readings,which could lead to

Strona 6

No. Symbol Meaning 11 A Amperes (amps). The unit of current.Display Symbols(2) (see figure 2)mV, V Volts

Strona 7 - Rules For Safe Operation (2)

Measurement Operation(1)WarningTo avoid harms to you or damages to the Meter fromeletric shock, do not attempt to measure voltageshigher than 600V AC/

Strona 8

Measurement Operation(2)l When DC voltage measurement has been completed, disconnect the connection between the testing leads and the circui

Strona 9 - ( figure 1)

Measurement Operation(3)Notel In each range, the Meter has an input impedance of 10MΩ. This loading effect can cause measurement errors in h

Strona 10 - Rotary Switch

Measurement Operation(4)The resistance ranges are:200.0, 2.000k , 20.00k ,200k ,2.000M and 20.00M .To measure resistance, connect the Meter as follow

Strona 11 - Functional Buttons(1)

Measurement Operation(5)D.Testing Diodes (see figure 6) red black( figure 6)WarningTo avoid damages to the Meter or to the devices undertest, dis

Strona 12 - (K-Type)

Table of ContentsTitle PageOverviewUnpacking InspectionSafety InformationRules F

Strona 13 - (see figure 2)

Measurement Operation(6)Notel In a circuit, a good diode should still produce a forward voltage drop reading of 0.5V to 0.8; however, the

Strona 14

Measurement Operation(7)WarningTo avoid damages to the Meter or to the devices undertest, disconnect circuit power and discharge all thehigh-voltage c

Strona 15 - Measurement Operation(1)

Measurement Operation(8)F. Temperature Measurement (UT202 Only) (see figure 8)The temperature measurement ranges are -40oC~1000oCand -40oF~1832oF

Strona 16 - Measurement Operation(2)

Measurement Operation(9)G. AC Current Measurement (see figure 9)( figure 9)WarningTo avoid electric shock, never measure current whilethe test leads

Strona 17 - Measurement Operation(3)

Measurement Operation(10)Note:l To obtain accurate reading, measure only one conductor at each time.l When current measurement has been complete

Strona 18 - Measurement Operation(4)

25To preserve battery life, the Meter automatically turnsoff if you do not turn the rotary switch or press any buttonfor around 15 minutes.The Meter c

Strona 19 - Measurement Operation(5)

SpecificationsA.General Specifications:l Maximum voltage including transient overvoltage between any terminals and grounding: 500V rms.l Display:

Strona 20 - Measurement Operation(6)

Accuracy: (a% reading + b digits), guarantee for 1 year.Operating temperature: 23oC 5oCRelative humidity: 75%R.HTemperature coefficient: 0.1x(speci

Strona 21 - Measurement Operation(7)

Accurate Specifications(2)C. Resistance: Auto ranging200.0Ω2.000kΩ20.00kΩ200.0kΩ2.000MΩ20.00MΩRange Resolution(1%+2)OverloadProtectionAccuracy(1.2%+2)

Strona 22 - Measurement Operation(8)

Accurate Specifications(3)F. Temperature (UT202 Only):Range ResolutionOverloadProtectionAccuracy-40~1000oC-40oF~1832oF1oC1oF-40~0oC:(3%+4)0~400oC:(1%+

Strona 23 - Measurement Operation(9)

OverviewThis Operating Manual covers information on safetyand cautions. Please read the relevant informationcarefully and observe all the Warnings and

Strona 24 - Measurement Operation(10)

MAINTENANCE(1)This section provides basic maintenance informationincluding battery replacement instruction.WarningDo not attempt to repair or service

Strona 25 - Sleep Mode

MAINTENANCE(2)WarningTo avoid false readings, which could lead to possibleelectric shock or personal injury, replace the batteryas soon as the battery

Strona 26 - Specifications

Copyright 2001 Uni-Trend Group Limited.All rights reserved.Manufacturer:Uni-Trend Technology (Dongguan) LimitedDong Fang Da DaoBei Shan Dong Fang Indu

Strona 27 - Accurate Specifications(1)

In the event you find any missing or damage, pleasecontact your dealer immediately.Unpacking InspectionOpen the package case and take out the Meter. C

Strona 28 - Accurate Specifications(2)

Safety InformationThis Meter complies with the standards IEC61010: inpollution degree 2, overvoltage category (CAT. II 600V,CAT. III 300V) and double

Strona 29 - Accurate Specifications(3)

Rules For Safe Operation (1)l Before using the Meter inspect the case. Do not use the Meter if it is damaged or the case (or part of the ca

Strona 30 - MAINTENANCE(1)

Rules For Safe Operation (2)l When the Meter working at an effective voltage over 60V in DC or 30V rms in AC, special care should be taken

Strona 31 - MAINTENANCE(2)

International Electrical SymbolsAC (Alternating Current).DC (Direct Current).AC or DC.Grounding.Double Insulated.Continuity Test.Diode.Fuse.Warning.

Strona 32

9The Meter Structure (see figure 1)( figure 1)1. Input Terminals2. LCD Display3. Functional Buttons4. Rotary Switch5. Trigger: press t

Komentarze do niniejszej Instrukcji

Brak uwag