Strona 1 - OPERATING MANUAL

Model UT207/208OPERATING MANUAL

Strona 2

Replace the battery as soon as the battery indicator appears. With alow battery, the Meter might produce false readings that can lead to electrics

Strona 3

International Electrical SymbolsAC (Alternating Current)DC (Direct Current)AC or DCGroundingDouble InsulatedWarning. Refer to the Operating ManualDefi

Strona 4

Figure 1The Meter Structure (see figure 1)Hand Guards: to protect user’s handfrom touching the dangerous area.Trigger: press the lever to open thetra

Strona 5 - Overview

Press SELECT button to select the alternate functions includingV , , %Hz, A and (UT208 only).Starts recording of maximum and minimum

Strona 6 - Unpacking Inspection

Press HOLD button for 2 seconds when turning on the Meter todisplay full icon.Button Operation PerformedHOLDWhen the Meter is at %Hz, V

Strona 7 - Safety Information

SELECT MAX/MINHOLDHzZERON/A%Hz66A1000A66A1000AN/AN/AN/AN/AN/AN/AN/AN/AN/AN/AN/AN/ARotary SwitchPositionsVFunctional ButtonsThe Effectiveness of Funct

Strona 8 - Rules For Safe Operation

Figure 2Display Symbols (see figure 2)Model UT207/208: OPERATING MANUAL15

Strona 9

Number Symbol Meaning1234567891011INRUSHMINMAXZEROIndicator for Surge currentMinimum reading displayedMaximum reading displayedIndi

Strona 10

Number Symbol Meaning12131415161718192021Sleep mode is onTest of diodeThe continuity buzzer is on: Ohm. The unit of resistance.k

Strona 11

A. DC/AC Voltage Measurement (see figure 3)To avoid harms to you or damages to the Meter from eletric shock, do notattempt to measure voltages higher

Strona 12

Table of ContentsTitle PageOverviewUnpacking InspectionSafety InformationRules For Safe OperationInternational Electrical SymbolsThe Meter StructureFu

Strona 13 - Functional Buttons

The DC Voltage ranges are: 6.6V, 66V and 600VThe AC Voltage ranges are: 6.6V, 66V and 600VTo measure DC/AC voltages, connect the Meter as follows:In

Strona 14

B. Measuring Resistance (see figure 4)To avoid damages to the Meter or to the devicesunder test, disconnect circuit power anddischarge all the high-vo

Strona 15

Connect the test leads across with the object being measured.The measured value shows on the display.3.NoteTo obtain a more precise reading, you could

Strona 16 - (see figure 2)

C. Testing Diodes (see figure 5)To avoid damages to the Meter or to the devicesunder test, disconnect circuit power anddischarge all the high-voltage

Strona 17

Insert the red test lead into the V Hz terminal and black test lead into the COMterminal.Set the rotary switch to . Press SELECT to switch to measur

Strona 18

D. Testing for Continuity (see figure 6)To avoid damages to the Meter or to the devicesunder test, disconnect circuit power anddischarge all the high-

Strona 19 - Measurement Operation

a circuit under test is higher than 100 .NoteWhen continuity testing has been completed, disconnect the connection betweenthe testing leads and the ci

Strona 20

E. Frequency Measurement (see figure 7)To avoid harms to you or damages to the Meterfrom eletric shock, do not attempt to measurevoltages higher than

Strona 21

NoteWhen frequency measurement has been completed, disconnect the connectionbetween the testing leads and the circuit under test, and remove the testi

Strona 22

F. Duty Cycle Measurement (see figure 8)To avoid harms to you or damages to the Meterfrom eletric shock, do not attempt to measurevoltages higher than

Strona 23 - Figure 5

Title Page30323537383839404041424243444545 G. DC Current Measurement H. AC Current Measurement I. UT208 only: Temperature Measure

Strona 24

NoteWhen duty cycle measurement has been completed, disconnect the connectionbetween the testing leads and the circuit under test, and remove the test

Strona 25 - Red Black

G. DC Current Measurement (see figure 9)The measurement ranges of current are: 66A and 1000A .To measure current, do the following:Set the rotary sw

Strona 26

NoteIf the Meter does not display 00.00 when it is at 66A range, press ZERO tozeroing. After zeroing, it allows 10 digits bouncing reading.When the

Strona 27

H. AC Current Measurement (see figure 10)The measurement ranges of current are: 66.00A and 1000A .To measure AC current, do the following:Set the ro

Strona 28

transformer jaw, otherwise it will casue deviation. The Meter can only measureone conductor at a time, to meausre more than one condutor at a time wi

Strona 29

When current measurement has been completed, disconnect the connectionbetween the conductor under test and the jaw, and remove the conductor awayfrom

Strona 30

I. UT208 only: Temperature Measurement (see figure 11)The temperature measurement range: -40 ~1000and -40 ~1832 .To measure temperature measurement, c

Strona 31

When the Meter is at range, it beeps to remind user to insert temperatureprobe.The Meter automatically displays the room temperature when the tempe

Strona 32

Sleep ModeTo preserve battery life, the Meter automatically turns off if you do not turn the rotaryswitch or press any button for around 15 minutes.Th

Strona 33

SpecificationsA. General Specifications:Maximum Voltage between any Terminals and grounding: Refer to different rangeinput protection voltage.Display

Strona 34

Title Page4748494950 I. AC Current J. Temperature (UT208 only)Maintenance A. General Service B. Replacing the BatteryModel

Strona 35

Battery Life: typically 150 hours (alkaline battery)Dimensions: 285.3mm x 105mm x 44.5mmWeight: Approximate 533g (battery included)B. Environmental R

Strona 36

Accurate SpecificationsAccuracy: (a% reading + b digits), guarantee for 1 year.Operating temperature: 23 5Relative humidity: 80%R.HTemperature co

Strona 37

B. AC VoltageRange6.600V66.00V600.0VResolution1mV10mV100mVAccuracy (1.2%+5)Overload protection600V DC/ACRemarks:Input Impedance: 10MFrequency Response

Strona 38 - Sleep Mode

C. ResistanceRange660.0Ω6.600kΩ66.00kΩ660.0kΩ6.600MΩ66.00MΩResolution0.1Ω1Ω10Ω100Ω1kΩ10kΩAccuracy (1.2%+2) (1%+2) (1.2%+2) (1.5%+2)Overload protection

Strona 39 - Specifications

E. Continuity TestRange Resolution0.1AccuracyAround 30Ω,thebuzzer beeps.(Open circuit voltageapprox. –1.2V)Overload protection250VACRemark:The buzzer

Strona 40

F. FrequencyRange660.0Hz6.600kHz66.00kHz660.0kHz6.600MHz66.00MHzResolution0.1Hz0.001kHz0.01kHz0.1kHz0.001MHz0.01MHzAccuracy (0.1%+3)Overload protectio

Strona 41 - Accurate Specifications

G. Duty CycleRange0.1%~99.9%Resolution0.1%AccuracyFor reference onlyOverload protection250VACH. DC CurrentRange66.00A1000AResolution0.01A1AAccuracy (2

Strona 42

Remarks:If the reading is positive, the current direction is from bottom to up. See figure10, the front case face up while the bottom case face down.

Strona 43

I. AC CurrentRange66.00A1000AResolution0.01A1AAccuracy (2%+40) (2%+8)Overload protection250VACFrequencyResponse50Hz ~ 60HzThe operating temperature mu

Strona 44

Non sine wave must follow the below data to adjust:Peak factor: 1.4~2.0, add 1.0% on the stated accuracy.Peak factor: 2.0~2.5, add 2.5% on the stated

Strona 45

OverviewThis Operating Manual covers information on safety and cautions. Please read therelevant information carefully and observe all the Warnings an

Strona 46

This section provides basic maintenance information including battery replacementinstruction.Do not attempt to repair or service your Meter unless you

Strona 47

B. Replacing the Battery (see figure 12)Figure 12To avoid false readings, which could leadto possible electric shock or personalinjury, replace the ba

Strona 48

To replace the battery:1. Turn the Meter off and remove all the connections from the input terminals2. Turn the Meter’s front case down.3. Remove the

Strona 49

* END *This operating manual is subject to change without notice.Model UT207/208: OPERATING MANUAL52

Strona 50 - MAINTENANCE

Copyright 2007 Uni-Trend Group Limited.All rights reserved.Manufacturer:Uni-Trend Technology (Dongguan) LimitedDong Fang Da DaoBei Shan Dong Fang Indu

Strona 51

Item Description Qty12345English Operating ManualTest LeadPoint Co

Strona 52

Safety InformationThis Meter complies with the standards IEC61010-1; IEC61010-2-032: in pollutiondegree 2, overvoltage category (CAT. II 600V, CAT. II

Strona 53

Rules For Safe OperationTo avoid possible electric shock or personal injury, and to avoid possibledamage to the Meter or to the equipment under test,

Strona 54

from the input terminals of the Meter and turn the Meter power off.The rotary switch should be placed in the right position and no anychangeover of ra