Model UT50A/B/C: OPERATING MANUAL
1
Table of Contents
Title
Overview
Unpacking Inspection
Safety Information
Rules For Safe Operation
International Electrical Symbols
The multimeter Structure
Functional Buttons
Display Symbols
Measurement Operation
A. DC Voltage Measurement
B. AC Voltage Measurement
C. DC Current Measurement
D. AC Current Measurement
E. Measuring Resistance
F. The Model UT50C:
Frequency Measurement
G. The Model UT50B/UT50C:
Temperature Measurement
H. Capacitance Measurement
I. Measuring Diodes & Continuity
General Specifications
Testing for Continuity
Sleep Mode
Turning on the Auto Display Backlight
Accuracy Specifications
A. DC Voltage
B. AC Voltage
C. DC Current
D. AC Current
Przeglądanie stron 0
1 2 3 4 5 6 ... 33 34

Podsumowanie treści

Strona 1 - Table of Contents

Page345689101113131416171920212223242525262727272828Model UT50A/B/C: OPERATING MANUAL 1Table of ContentsTitleOverviewUnpacking InspectionSafety Infor

Strona 2 - Maintenance

10Functional ButtonsButton Operation PerformedTurn the Meter on and off.l Press down the POWER to turn on the Meter.l

Strona 3 - Overview

11Display Symbols (see figure 2)( figure 2)No. Symbol Meaning1Dangerous Voltages.2The battery is low. Warning: To avoid fals

Strona 4 - Unpacking Inspection

12Display Symbols (see figure 2)No. Symbol MeaningnF, µF12F: Farad. The unit of capacitance.µF: Microfarad.1 x 10-6 or 0.00

Strona 5 - Safety Information

Measurement Operation(1)A. DC Voltage Measurement (see figure 3)WarningTo avoid harms to you or damages to the Meter fromelectric shock, please do not

Strona 6 - Rules For Safe Operation (1)

14Measurement Operation(2)Notel If the value of voltage to be measured is unknown, use the maximum measurement position (1000V) and reduce

Strona 7 - Rules For Safe Operation (2)

15The Model UT50A: The AC voltage measurement has5 measurement positions on the rotary switch: 200mV,2V, 20V, 200V and 750VThe Model UT50B/UT50C: The

Strona 8

16Measurement Operation(4)C. DC Current Measurement (see figure 5)WarningNever attempt an in-circuit current measurementwhere the open circuit voltage

Strona 9

2. Insert the red test lead into the µAmA (The Model UT50B/UT50C) or 20A terminal and the black test lead into the COM terminal.3. Set t

Strona 10 - Functional Buttons

18Measurement Operation(6)WarningNever attempt an in-circuit current measurementwhere the voltage between terminals and ground isgreater than 60V.If t

Strona 11 - ( figure 2)

19E. Measuring Resistance (see figure 7)WarningTo avoid damages to the Meter or to the devices undertest, disconnect circuit power and discharge all t

Strona 12

Page292929I. Diodes and Continuity Test3030C. Replacing the Fuses31323232Model UT50A/B/C: OPERATING MANUAL 2TitleE. Resistance Tes

Strona 13 - Measurement Operation(1)

20 measured resistance value (Y) – (X) = precision readings of resistance.l For high resistance (>1MΩ), it is normal taking sever

Strona 14 - Measurement Operation(2)

21Notel When Hz measurement has been completed, disconnect the connection between the testing leads and the circuit under test.G. The Model

Strona 15 - Measurement Operation(3)

22l The included temperature probe can only be measured up to 250oC For any mesaurement higher than that, the rod type temperature probe m

Strona 16 - Measurement Operation(4)

23Measurement Operation(11)Notel For testing the capacitor with polarity, connect the red test lead to anode & black test lead to cathodel Wh

Strona 17 - Measurement Operation(5)

24Measurement Operation(12)Notel In a circuit, a good diode should still produce a forward voltage drop reading of 0.5V to 0.8V; however; the

Strona 18 - Measurement Operation(6)

Sleep Mode25Turning on the Auto Display BacklightThe Meter has a built-in sensor. Therefore the DisplayBacklight turns on and off automatically depen

Strona 19 - Measurement Operation(7)

26General Specificationsl Maximum voltage between any Terminals and Grounding : 1000V rms.l Fused Protection for

Strona 20 - Measurement Operation(8)

27Accuracy Specifications(1)Accuracy: (a% reading + b digits),guarantee for 1 year.Operating temperature:23oC5oC.Relative humidity:<75%.Temperatur

Strona 21 - Measurement Operation(9)

28Accuracy Specifications(2)C. DC CurrentRangeResolution(0.8%+1)OverloadProtection UT50A UT50B UT50CAccuracy(2%+5)20µA2mA20mA200mA20

Strona 22 - Measurement Operation(10)

29E. Resistance TestAccuracy Specifications(3)200Ω2kΩ20kΩ200kΩ2MΩ20MΩ200MΩRangeResolution(0.8%+3)OverloadProtectionUT50A UT50B UT50CAccuracy(1%+2)0.1Ω

Strona 23 - Measurement Operation(11)

OverviewWarningTo avoid electric shock or personal injury, read the"Safety Information" and "Rules for Safe Operation"carefully be

Strona 24 - Measurement Operation(12)

30Accuracy Specifications(4)RangeResolution(4%+3)OverloadProtection UT50A UT50B UT50CAccuracy(4%+3)H. Capacitance2nF20nF200nF2µF100µF1pF10pF0.1nF

Strona 25 - Sleep Mode

31Maintenance(1)This section provides basic maintenance informationincluding battery and fuse replacement instruction.WarningDo not attempt to repair

Strona 26 - General Specifications

32Maintenance(2)WarningTo avoid false readings, which could lead to possibleelectric shock or personal injury,replace the batteryas soon as the batter

Strona 27 - Accuracy Specifications(1)

33Model UT50A/B/C: OPERATING MANUALMaintenance(3)1. Install ONLY replacement fuses with the identical type and specification as follows and m

Strona 28 - Accuracy Specifications(2)

34Manufacturer: UNI-TREND TECHNOLOGY(DONG GUAN)LIMITEDAddress: Dong Fang Da Dao, Bei Shan Dong Fang Industrial Development District, Hu

Strona 29 - Accuracy Specifications(3)

Unpacking InspectionOpen the package case and take out the Meter. Checkthe following items carefully to see any missing ordamaged part:In the event y

Strona 30 - Accuracy Specifications(4)

Safety InformationThis Meter complies with the standards IEC61010: inpollution degree 2, overvoltage category (CAT. II 1000V,CAT. III 600V) and double

Strona 31 - Maintenance(1)

Rules For Safe Operation (1)WarningTo avoid possible electric shock or personal injury,and to avoid possible damage to the Meter or to theequipment un

Strona 32 - appears

Rules For Safe Operation (2)l Disconnect circuit power and discharge all high- voltage capacitors before testing resistance, continuity, dio

Strona 33 - Maintenance(3)

International Electrical SymbolsAC (Alternating Current).DC (Direct Current).AC or DC.Grounding.Double Insulated.Deficiency of Built-In Battery.Contin

Strona 34

The multimeter Structure (see figure 1)9( figure 1)1 LCD Display2 Data Hold Button.3 Rotary Switch4 Other Input Terminals5 COM Input Termina